![]() ![]() The LED control is configured using keypad options 19, 20, 21 and 22, which are programmed with command 30. ![]() The operation of these LED's in Wiegand Mode is determined by the LED control wire (brown) and how it is configured. Iei 232i programming manual / iei technology 212em installationWiring diagram to maglock iei keypad Keypad iei access control 2000 2000e flush backlit mount series styleIei technology upc-v312-d525 user manual pdf download. *Note: The Red/Green LED descriptions above are for Standalone and Secured Series Mode only. Sounder ¼ sec on, ¼ sec off Audio Alert 1 Beep Every 2 seconds LED's Cycling Left to Right Over Voltage Warning LED's Cycling Right to Left Under Voltage Warning 3 Rapid Beepsġ Long Beep, 3 Short Beeps Access Denied, User Lockout 1 Long Beep, 5 Short Beeps Access Denied, Code Mismatch 6 Quick Beeps Please refer to the Wiegand Interface Module instructions 6065700 Rev 1.0, the HubMax II Instructions 6065034 Rev 3.4 and the Hub MiniMax II instructions 6055037 Rev 3.3 for complete details. After entering the command to program a card user, enter the code on the 2000e/eM keypad to send the data to the controller. For example, when programming a user into an IEI Door Control Module, you must program the user as though you were programming a card. When the keypad is configured in Wiegand mode, the keypad data is sent as a complete Wiegand data packet, as though you presented a card. The keypad supports the following Wiegand formats (parameter 10). Check Details Iei technology 212em keypad installation & programming manual. Note: This does not reset the keypad operating mode. Iei 2000e backlit keypadIei 2000e manual Iei 212r keypad programming manual : 410upc v312 panel pc user manualIei keypad 2000 flush durable em mount access control metal series style. All access control functionality should be programmed and remain separate from the Panic Output functionality. This output should not be used to gain access. This is used in case of emergency to activate an auxiliary alarm device, such as a siren, that is used to indicate an emergency condition only. *Note: The Panic Output is activated by pressing the * and # keys at the same time. Note: The default setting for both settings is 0. Note: Refer to the Wiegand Format Chart below for parameter 8. 12 – Wiegand Interpulse Spacing 1 – 255 ( default = 32, 640µS) ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |